Ovation™ Model 3400
The Ovation™ 3400 series is one of the best selling commercial tanning beds of our time! No wonder; striking good looks, fits in a 7’ x 8’ room and designed in several lamp configurations to meet your salon needs. You choose; 10, 15 or 20 minute maximum session. The 10, 15 and 20 minute variations are available with an optional triple face tanner totaling 1200 watts of power. Accessible countdown digital timer is standard. This bed will last for years and give you the peace of mind that only steel construction can provide.
 

 

 

 
Specifications for Ovation™ 3400:

34 Lamp Heartland Rave system – 20 minute session
18 Heartland Rave 5071 100 watt lamps in canopy
16 Heartland Rave 5071 100 watt lamps in bench
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 208 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*24 AMPS initial start up, 21 AMPS running at 220 VAC
.75 KVA Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 755lbs.
Dimensions: 871/2”L X 421/2”W
5 Year Limited Warranty

Type B seal tight connector supplied. Located lower back in center of bed. Type B flexible conduit required. *Actual amp reading will vary depending on voltage-electrician must calculate load/line side amps when using a Buck/Boost transformer to insure proper wire gauge and breaker size. Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow less than 2% voltage drop up to 100 feet. Licensed electrician must refer to National Electric Codes when determining proper wire gauge and breaker size for each application. All specifications are subject to change.

Specifications for Ovation™ 3400/3:

34 Lamp Heartland Rave system – 20 minute session
18 Heartland Rave 5071 100 watt lamps in canopy
16 Heartland Rave 5071 100 watt lamps in bench
(3) 400 watt facial lamps
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*24 AMPS initial start up, 26 AMPS running @ 220 VAC
.75 Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 797lbs.
Dimensions: 871/2”L X 421/2”W
5 Year Limited Warranty

Type B seal tight connector supplied. Located lower back in center of bed. Type B flexible conduit required. *Actual amp reading will vary depending on voltage-electrician must calculate load/line side amps when using a Buck/Boost transformer to insure proper wire gauge and breaker size. Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow less than 2% voltage drop up to 100 feet. Licensed electrician must refer to National Electric Codes when determining proper wire gauge and breaker size for each application. All specifications are subject to change.

Specifications for Ovation™ 3400R:

34 Lamp Heartland Rave system – 15 minute session
18 Heartland Rave 10071 R 100 watt lamps in canopy
16 Heartland Rave 10071 R 100 watt lamps in bench
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*24 AMPS initial start up, 21 AMPS running at 220 VAC
.75 KVA Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 755lbs.
Dimensions: 871/2”L X 421/2”W
5 Year Limited Warranty

Type B seal tight connector supplied. Located lower back in center of bed. Type B flexible conduit required. *Actual amp reading will vary depending on voltage-electrician must calculate load/line side amps when using a Buck/Boost transformer to insure proper wire gauge and breaker size. Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow less than 2% voltage drop up to 100 feet. Licensed electrician must refer to National Electric Codes when determining proper wire gauge and breaker size for each application. All specifications are subject to change.
 

Specifications for Ovation™ 3400R/3:

34 Lamp Heartland Rave system – 15 minute session
18 Heartland Rave 10071 R 100 watt lamps in canopy
16 Heartland Rave 10071 R 100 watt lamps in bench
(3) 400 watt facial lamps
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*24 AMPS initial start up, 26 AMPS running @ 220 VAC
.75 Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 797lbs.
Dimensions: 871/2”L X 421/2”W
5 Year Limited Warranty

Type B seal tight connector supplied. Located lower back in center of bed. Type B flexible conduit required. *Actual amp reading will vary depending on voltage-electrician must calculate load/line side amps when using a Buck/Boost transformer to insure proper wire gauge and breaker size. Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow less than 2% voltage drop up to 100 feet. Licensed electrician must refer to National Electric Codes when determining proper wire gauge and breaker size for each application. All specifications are subject to change.
 

Specifications for Ovation™  3400S:

34 Lamp Heartland Rave system – 10 minute session
18 Heartland Rave Select 100 watt lamps in canopy
16 Heartland Rave Select 100 watt lamps in bench
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*24 AMPS initial start up, 21 AMPS running at 220 VAC
.75 KVA Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 755lbs.
Dimensions: 871/2”L X 421/2”W
5 Year Limited Warranty

Type B seal tight connector supplied. Located lower back in center of bed. Type B flexible conduit required. *Actual amp reading will vary depending on voltage-electrician must calculate load/line side amps when using a Buck/Boost transformer to insure proper wire gauge and breaker size. Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow less than 2% voltage drop up to 100 feet. Licensed electrician must refer to National Electric Codes when determining proper wire gauge and breaker size for each application. All specifications are subject to change.
 

Specifications for Ovation™ 3400S/3:

34 Lamp Heartland Rave system – 10 minute session
18 Heartland Rave Select 100 watt lamps in canopy
16 Heartland Rave Select 100 watt lamps in bench
(3) 400 watt facial lamps
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*24 AMPS initial start up, 26 AMPS running @ 220 VAC
.75 Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 797lbs.
Dimensions: 871/2”L X 421/2”W
5 Year Limited Warranty

Type B seal tight connector supplied. Located lower back in center of bed. Type B flexible conduit required. *Actual amp reading will vary depending on voltage-electrician must calculate load/line side amps when using a Buck/Boost transformer to insure proper wire gauge and breaker size. Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow less than 2% voltage drop up to 100 feet. Licensed electrician must refer to National Electric Codes when determining proper wire gauge and breaker size for each application. All specifications are subject to change.
 
 

Contact Our Sales Department

HomeAbout UsContactsTestimonialsEmployment Opportunities
Online Order FormTanning Location MapLease Application
Warranty RegistrationUPS TrackingManuals & Technical Information
Corporate Web Mail
 
Copyright © 2006-2007 Heartland Tanning, Inc.
800.554.8268 |816.795.1414| Fax 800.900.9390
E-mail: Heartland@heartlandtan.com