The Encore™ combines style and solid steel construction for rigid durability.
It's no secret the Rave™ 180 APR 180 lamps produce more heat than traditional
tanning lamps. That's why we've taken extra time to develop features that cool
the customer while tanning and exhaust oppressive heat from the tanning room.
Two 1350 cfm fans (like the ones in your furnace at home) pull the heat away
from the client and out of the room, keeping your salon and your customers cool.
Impressive back-lighting and frosted acrylics are standard features. Our spring
lift system makes raising and lowering the lid an effortless experience.
Hinged acrylic makes routine maintenance and cleaning a snap. Your customers
will love the results and you will appreciate the quick 12 minute maximum
session time! To incorporate this bed in your salon we recommend a minimum
room size of 8’ x 9’.
Specifications for ENCORE™ 164/4:
44 Lamp Heartland Rave system - 12 minute session
24 Heartland Rave 160 APR 160 watt lamps in canopy
20 Heartland Rave 180 APR 180 watt lamps in bench
(4) 500 watt facial lamps
T-Max timer on board (T-Max wireless compatible)
(2) Easy roll-out component trays underneath bench
12” round heat exhaust ventilation required
600 CFM integrated body cooling system
*70 AMP rated single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*58 AMPS initial start up, 56 AMPS running @ 220 VAC
2.0 KVA Buck/Booster transformer required if outside 220 – 240 VAC
8’ X 9’ minimum room size required
2 Ton (24,000 BTU) minimum A/C dedicated into room
Shipping weight: 1635lbs
Dimensions: 871/2”L X 55”W
5 Year Limited Warranty
Type B seal tight connector supplied. Located lower back in center of bed.
Type B flexible conduit required. *Actual amp reading will vary depending on
voltage-electrician must calculate load/line side amps when using a Buck/Boost
transformer to insure proper wire gauge and breaker size.
Minimum 4 gauge wire size is recommended for this 70 amp circuit to allow less
than 2% voltage drop up to 120 feet. Licensed electrician must refer to
National Electric Codes when determining proper wire gauge and breaker size for
each application. All specifications are subject to change.